This guide demonstrates the ways in which the fibre connections for PPM Test products can be cleaned.

For Sentinel 3 optical ports, Neutrik connectors are used. For point2point products, the standard optical port is FC/APC. Details for cleaning both types of products can be found here.

Sentinel 3 TX & RX Unit

The Sentinel 3 cleaning kit (PPM part number: 72796) contains all of the cleaning equipment detailed here. These items can also be purchased separately (contact us). 

Depending upon the selected product, the Sentinel 3 TX and RX optical ports will be either duo/quad core, or MTP. To clean the Sentinel 3 connector socket, use the dry cleaning tools.

Insert the cleaner into the socket and push until you hear a click. Once this has been heard you can remove the cleaner. The socket has now been cleaned.

Sentinel 3 fibre connectors (cleaning)

For Standard Duplex LC connectors (TX1 and TX8 – Duo, RX1 and RX2 Duo and Quad) use the IBC cleaner. For MPO/MTP (RX6) connectors use the MTP in bulkhead cleaner.

Insert the cleaner into the socket and push until you hear a click. Once this has been heard you can remove the cleaner. The socket has now been cleaned.

Sentinel 3 fibre connectors (deep cleaning)

Occasionally, depending on usage, it may be necessary to deep clean the Neutrik Fibre connectors. This involves removing the connector receptacles to access the internal fibres in the cable. The four images below details which Stickler cleaning tool is required to clean each type of fibre. 

                 

MCC-S12 for cleaning LC end face                              MCC-XMT for cleaning MPO fibres

                       

MCC-S25 for cleaning exposed fibre ferrules             Cleaning fluid (for use with cleaning sticks)

To deep clean the Sentinel 3 fibre connectors, pull the spring washer towards the end of the connector and rotate anti-clockwise (ensure the fibre cable itself does not rotate while actioning this).

When the fibre is exposed, use the ends of the stickler pads to gently clean the ends of the fibre. The stickler pads are supplied with the cleaning kit, but are also available separately.

An example of how to expose and clean the fibres using the sticklers:

RX6 Heavy Duty Cable

RX1 Lightweight Cable

Cleaning point2point receptacles and fibres

point2point products utilise the FC/APC connector. This connector is designed to lock in place and prevent dirt and dust ingress.

In order to clean the cables, a cleaning kit needs to be purchased from PPM Test.

To clean the optical receptacle, use the sticklers provided with the cleaning kit, and optionally the cleaning fluid too, as shown here.

 A demonstration of how the cleaning should be actioned within the kit is shown below:

Fibre Cleaning Kit In Use

  1. Peel the plastic cover from an unused ‘N’ cleaning pad. 
  2. Hold the connector between your thumb and forefinger.
  3. Clean the connector using the pressure by swiping in a pendulum motion through each segment of the ‘N’ shape, following the diagram.
  4. Do not swipe the same space twice. 

Fibre Cleaning Kit Demonstration