Description
The PRODYN KWIK-LATCH® current probes are wideband devices designed to measure current on cable bundles and other RF sources without disconnecting the conductor. The probes have a mid-sized aperture of 1.25 ” and a durable and easy to use hinged two piece design. The I-125 Current Probes have a 50 Ω output load impedance and come with a type ‘N’ connector as standard. Other connector types are available.
Specifications
Model | Zt Ω | Usable Frequency Range | 3 dB Points |
---|---|---|---|
I-125-1A | 5 | 10 kHz - 100 MHz | 110 kHz - 90 MHz |
I-125-1D | 5 | 1 kHz - 110 MHz | 25 kHz - 80 MHz |
I-125-1E | 5 | 850 Hz - 120 MHz | 5 kHz - 70 MHz |
I-125-1 HF | 5 | 50 kHz - > 1 GHz | 120 kHz - >600 MHz |
I-125-2A | 1 | 10 kHz - 150 MHz | 30 KHz - 80 MHz |
I-125-2C | 1 | 300 Hz - 25 MHz | 600 Hz - 10 MHz |
I-125-2E | 1 | 1 kHz - 200 MHz | 3.1 kHz - 181 MHz |
I-125-2 HF | 1 | 50 kHz - > 1 GHz | 80 kHz - > 500 MHz |
I-125-7A | 1 | 400 Hz - 100 MHz | 540 Hz - 30 MHz |
I-125-6A | 0.5 | 20 Hz - 30 MHz | 60 Hz - 10 MHz |
I-125-4A | 0.1 | 1 kHz - 150 MHz | 4 kHz - 110 MHz |
I-125-3A | 0.03 | 1 kHz - 250 MHz | 10 kHz - 180 MHz |
I-125-9A | 0.005 | 1 kHz - 270 MHz | 10 kHz - 200 MHz |