Inductive Current Probes (I-dot Sensors)

Inductive Current Probes (I-dot Sensors)

Description

The RID-200 I-dot sensors are 2 or 4-turn toroidal mutual inductance current probes designed to measure the first time derivative of the total current through the toroid aperture. Applications include measurements of the current in a wire, structure or other conductor passing through the aperture, or a free space current such as a charged particle beam. The standard configuration is a fixed aperture with a differential 100 ohm output, but a split version and other output connector options can be provided on special order. Optional radiation hardened models are available.

Electrical Specifications

ModelM (nH)Freq. Resp (3 dB MHz)Risetime (ns)Max Output (kV)Output Imp (Ω)OutputOutput Connector
RID-2102> 700< 0.55100DiffTCC
RID-2202.5> 350< 15100DiffTCC
RID-23010> 700< 0.55100DiffTCC
RID-2400.5> 1400< 0.25550Sgl EngType N
RID-25010> 300< 0.35100DiffTCC
RID-26010> 1400< 0.255100DiffTCC
RID-2655> 1000< 0.202100DiffSMA
RID-27010> 1400< 0.255100DiffTCC
RID-29010> 280< 1.255100DiffTCC

Physical Specifications

ModelAperture Diameter (cm)Overall Diameter (cm)Height (cm)Stem Projection (cm)Mass (kg)
RID-2109.715.2435.721.55
RID-22019.134.936.535.7212.49
RID-23010.0117.787.625.721.63
RID-2409.8315.243.183.185.5
RID-25019.134.936.535.7212.49
RID-2603.818.265.085.721
RID-2653.186.993.18N/A0.12
RID-2701.916.353.815.720.75
RID-29049.9966.0412.075.725.45

Datasheet and Brochure