Description
PRODYN’s precision high frequency ground plane electric field (D-dot) sensors are designed to measure time rate-of-change of electric displacement over a wide frequency spectrum. They can also be used to measure the time rate-of-change of surface current density.
Surface or through-the-ground plane output configurations are available to allow testing flexibility. Testing has shown the asymptotic sensing element design to have less capacitance and higher upper frequency characteristics compared to older HSD (Hemi-Spherical D-dot) design.
Equiv. Area (Aeq) | Freq. Response (3 dB point) | Risetime (tr 10-90) | Max. Output | Output Connector (Female) | Mass | H (cm) - see outline | D (cm) - see outline | L (cm) - see outline | T (cm) - see outline | A (cm) - see outline | C (cm) - see outline | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
AD-S(10) | 1 × 10-4 m² | > 10 GHz | < 0.03 ns | +150 V | SMA | 16 g | 0.56 | 2.54 | 7.62 | 0.1 | - | 1.22 |
AD-(10) | 1 × 10-4 m² | > 10 GHz | < 0.03 ns | +150 V | SMA | 13 g | 0.56 | 2.54 | - | 0.1 | 1.5 | - |
AD-S(110) | 1 × 10-3 m² | > 3.5 GHz | < 0.10 ns | +1 kV | SMA | 70 g | 1.73 | 7.62 | 12.7 | 0.23 | - | 2.29 |
AD-110 | 1 × 10-3 m² | > 3.5 GHz | < 0.10 ns | +1 kV | SMA | 60 g | 1.73 | 7.62 | - | 0.23 | 1.91 | - |
AD-S(30) | 1 × 10-2 m² | > 1 GHz | < 0.35 ns | +4 kV | SMA | 546 g | 5.03 | 13.97 | 30.48 | 0.23 | - | 2.29 |
AD-30(A) | 1 × 10-2 m² | > 1 GHz | < 0.35 ns | +4 kV | SMA | 324 g | 5.03 | 13.97 | - | 0.25 | 1.83 | - |
AD-S(60) | 1 × 10-1 m² | > 400 MHz | < 1.0 ns | +5 kV | Type N | 1.5 kg | 15.54 | 28.24 | 55.88 | 0.3 | - | 4.11 |
AD-60(A) | 1 × 10-1 m² | > 400 MHz | < 1.0 ns | +5 kV | Type N | 1.3 kg | 15.54 | 28.24 | - | 0.3 | 5.72 | - |